Applied Analytics, Inc. is a global supplier of online analysis equipment serving the
oil, natural gas, chemical, and pharmaceutical industries. For over 20 years,
AAI has provided efficient and economical solutions to the most challenging
industrial applications using UV-Vis and NIR spectroscopy. AAI's flagship OMA-300 process analyzer andTLG-837 tail gas
analyzer help comprise
the comprehensive product line that suits many analytical requirements.
Products List
The TLG-837 tail gas
analyzer continuously
measures the chemical concentrations of H2S, SO2, COS,
and CS2 in the Claus
process tail gas stream. Using the patented in situ DEMISTER sampling probe and
a full-spectrum UV-Vis spectrophotometer, this system provides extremely fast,
accurate response for tight process control.
Features:
- Continuously measures
concentrations of H2S and SO2 (H2S/SO2 ratio) and outputs Air Demand
signal (user-defined formula)
- Patented DEMISTER
sampling probe with internal sulfur vapor removal
- Totally solid state
with no moving parts, sample lines, or heat tracing - modern design for
low maintenance
- Ultra-safe fiber optic
design - no toxic/explosive sample gas in analyzer enclosure
- Superior Off-Ratio
range ( 100:1 < H2S/SO2 ratio < 1:20 )
Measurements:
- H2S
- SO2
- COS
- CS2
- air demand
The OMA is an industrial device which measures a high-resolution
absorbance spectrum in a continuously drawn sample from a liquid or gas process
stream. Harvesting this rich data, the OMA process analyzer provides real-time
analytics for the process stream, including chemical concentrations, purity,
and color.
Chemical Concentrations:
The OMA can simultaneously monitor up to 5 chemicals in the
sample stream. All analytes must have distinct absorbance curves in the
200-1100nm UV-Vis/SW-NIR wavelength range to be measurable by the OMA.
Chemical Purity:
By measuring a high-resolution transmittance spectrum, the OMA
can very precisely detect impurities in the sample fluid by sudden changes in
the spectral structure.
Physical Properties:
Various properties such as the heating value of a fuel or the
octane of a gasoline blend can be powerfully correlated to the absorbance
spectrum of the sample.
Specialized OMA Solutions:
Two Explosion-proof Formats:
- Eexp - Eexp systems are
purged and pressurized using a certified air-purging device. This method
ensures that toxic/explosive gas is not allowed to accumulate inside the
enclosure, and is ideal when instrument air is available.
- Eexd - Eexd systems are
contained within certified explosion-proof cast-aluminum enclosures. This
method is more practical if the installation is remote or utilities are
unreliable.
Other OMA Models:
- OMA-206P Portable - The portable version
of the OMA Process Analyzer is housed in an ultra-rugged suitcase
enclosure, so you can bring analytics from site to site with confidence.
- OMA-406R Rackmount - The rackmount
version of the OMA is designed for easy integration in analyzer shelters
and laboratory settings.
The OMA H2S
analyzer continuously measures H2S concentration using a full-spectrum UV-Vis spectrophotometer, harvesting the
power of collateral data to establish excellent dynamic range and sustain
accuracy in the presence of cross-interfering species. With an ultra-safe fiber
optic design and solid state build, this system is simple to install and
relentlessly reliable.
Features:
- Continuously measures
H2S concentrations in a liquid or gas process stream
- Up to 4 additional
software benches for additional analytes (e.g. SO2 , R-SH)
- Totally solid state
build with no moving parts - modern design for low maintenance
- Ultra-safe fiber optic
design with dedicated sample flow cell - no toxic/corrosive sample fluid
in analyzer enclosure
- Decades of
field-proven performance in the world's harshest industrial environments
From the MicroSpec series comes the MCP-200, a concentration monitor for species that
absorb IR radiation. This solid state package combines a non-dispersive IR
detector and a proprietary optical path design. Engineered to be compact and
modular, the MCP-200 excels as both a rugged standalone and an integrated
component.
Measurements:
- carbon monoxide | CO
- carbon dioxide | CO2
- ethylene | C2H4
- methane equivalency |
CH4
- water | H2O
The automated gas mixing
system from Applied
Analytics utilizes cutting-edge mass flow controllers to achieve the precision
and repeatability required for demanding applications like research and instrument
calibration.
When a liquid is too opaque or dirty to transmit a light signal,
direct optical analysis may be impossible. In this case, the composition of the
liquid can be measured by heating the sample and analyzing the vaporous
'headspace' gas. The headspace sampling
system design uses
Henry's Law to provide a highly effective analytical solution for opaque
liquids, including: crude oil, dirty wastewater and amine solution.
Product URLs:
TLG-837 TAIL GAS / AIR DEMAND ANALYZER
[http://aai.solutions/tlg-837-tail-gas-air-demand-analyzer]
OMA H2S ANALYZER
[http://aai.solutions/oma-h2s-analyzer]
OMA-300 PROCESS ANALYZER
[http://aai.solutions/oma-process-analyzer]
MICROSPEC MCP-200 INFRARED ANALYZER
[http://aai.solutions/microspec_mcp-200-infrared-analyzer]
Mix-2000 DIGITAL GAS MIXER
[http://aai.solutions/mix-2000-digital-gas-mixer]
HEADSPACE SAMPLE CONDITIONERS
[http://aai.solutions/sampling#headspace]